Electrical Data |
Output waveform |
Paralell output push-pull. Serial interface: Line-driver according to RS 485, galvanically isolated by opto-couplers (SSI, Profibus, Devicenet, Canopen etc. |
|
Zero or index pulse |
(Z) one pr. Rev. |
|
Output |
Push-pull. RS422 line driver |
|
Supply-voltage (Vin) |
Min 4,5V to Max. 30V * Reverse polarity protection |
|
Current (no load) |
Max. 45 mA |
|
Max. load pr. output |
30 mA -(Short circuit protected) * |
|
V Out low |
Max. 500 mV @ I =10 mA |
|
Operating temp. |
- 40°C to + 85°C |
|
Storage temp. |
- 40°C to + 85°C |
|
Max. pulse frequency |
300 kHz * |
|
V out high |
Min. (Vin -0,6) @ I = -10mA Min. (Vin -1,3) @ I = -25mA |
|
Cable data |
8 leads (0,14 mm²) pair-twisted/shielded |
|
Output signals |
Standard, Inverted, Differential (RS-422A compatible,5V) |
|
Certified acc. to |
EN 50081-1 and EN 50082-2 |
|
|
|
|
DownLoad |
|
|